Twinfield: Installation & settings
Twinfield is a cloud-based accounting software that automatically synchronizes your financial transactions and journal entries from Booking Experts.
In our App Store you can read more about what Twinfield can offer you.
How to install the app?
Go to the 'Available apps' index, and use the search bar to find the Twinfield app. Click the 'Install app' button.
Read more: Getting started with BEX App integrations
Complete the settings
1. Authorize Twinfield
What you'll do:
Open the Twinfield app from your overview of installed apps.
Select 'Authorize Twinfield' from the Commands dropdown
You will be redirected to the Twinfield login page
Enter your Twinfield or Wolters Kluwer credentials
Grant permission for Booking Experts to access your Twinfield account
You will be redirected back with a confirmation message
Important Information:
You must have an active Twinfield account to authorize
Your credentials are never stored—only a secure OAuth token is used
If authorization fails, verify your Twinfield account permissions
You can reauthorize at any time if needed
What happens after: Your Twinfield account is now connected and authorized. You can now proceed to create accounting configurations to specify which administrations and financial data to sync to Twinfield.
2. Create configurations
What you'll do:
Open the Twinfield app from your overview of installed apps.
Select 'Configurations' from the Commands dropdown
Click "+ Configuration" to create a new accounting setup
Complete the configuration form (you may need to save and then edit to access all settings):
BEX administration: Select which PMS administration this configuration applies to
Twinfield administration: Select your administration in Twinfield
Frequency: Choose synchronization frequency (daily or monthly)
General Journal: Select the journal for posting transactions
Cost Center: Select a default cost center (if applicable)
Start Date: Define the start date for syncing transactions
End Date: Define the end date (optional)
Automatic sync: Enable to perform automatic synchronization based on the settings above
Automatic closure of accounting periods: Enable to automatically prevent changes to PMS accounting data after synchronization
Sync delay: Set the number of days to delay synchronization, a buffer period to ensure all relevant transactions are logged
Click "Save" to create the configuration
Important Information:
Each BEX administration should have its own configuration
Available choices for general journal and cost center settings are taken from the connected Twinfield account
Automatic closure of accounting periods simplifies month/year-end processes
Sync delay helps ensure all transactions are complete before syncing
What happens after: Your accounting configuration is created and ready to activate. The synchronization of your administration’s financial transactions to Twinfield can now begin.
Daily operation
1. Manage configurations
What you'll do:
Open the Twinfield app from your overview of installed apps.
Select 'Configurations' from the Commands dropdown
For each created configuration, you can see:
Configuration name
Active/Inactive status
Automatic sync status
To view or edit, click on the configuration name
Important Information:
Only active configurations sync transactions
Inactive configurations are preserved with all settings intact
Each configuration independently controls its sync schedule
All settings can be edited
What happens after: You can view all your Twinfield accounting configurations and their status.
2. Activate / deactivate a configuration
What you'll do:
Open the Twinfield app from your overview of installed apps.
Select 'Configurations' from the Commands dropdown
Open the relevant configuration
Click the "Activate" button (Or, the "Deactivate" button)
The configuration is immediately activated (Or, deactivated)
You will see a confirmation message: "Successfully activated" (Or, "Successfully deactivated)
If automatic sync is enabled, synchronization begins according to the schedule (Or, all synchronization is blocked, including manual synchronization)
Important Information:
Only one active configuration per administration is recommended
Deactivation is useful for temporary pauses or switching configurations
Reactivation doesn't require reconfiguring all settings
What happens after: If the configuration is (re-)activated, a manual synchronization is recommended. The manual synchronization button is found next to the "activate / deactivate” button.
3. Manually synchronize transactions
What you'll do:
Open the Twinfield app from your overview of installed apps.
Select 'Configurations' from the Commands dropdown
Open the relevant configuration
Click the "Synchronize" button
You will see a confirmation message: "Synchronization started successfully"
The system processes all new or updated transactions based on your settings
Important Information:
Manual sync can be triggered regardless of automatic sync settings
Sync includes all bookings, invoices, and financial entries within the date range
The system respects the configured sync delay
Automatic closure of accounting periods is triggered if enabled
The configuration shows the number of journal transactions synced
Errors are displayed with details for troubleshooting
Sync may take several minutes depending on transaction volume
What happens after: Journal entries are recorded in your Twinfield general ledger, and the next automatic sync will be scheduled according to the frequency settings.
4. Review journal transactions
What you'll do:
From the Configurations list, open an active configuration
Click "View" to access journal transactions by synchronization date range
View more details by clicking on the start date:
Transaction date
Reference information
Amount and currency
Journal entry details
Use search and filter options to find specific transactions by date or reference
Important Information:
Journal transactions represent all financial entries sent to Twinfield
Transactions include bookings, invoices, and other accounting entries
Transaction history is maintained for audit and compliance purposes
What happens after: You can verify all transactions have been properly synchronized. Financial reports can be generated in Twinfield using the synced data.
5. Resynchronizing failed or changed journal transactions
What you'll do:
From the Configurations list, open an active configuration
Click "View" to access journal transactions and see any entries that were not synchronized or which need to be updated
Click on the relevant journal entry to view any error message, which lists the failed lines
Make the necessary adjustments in BEX PMS
Resynchronize by clicking "Synchronize again"
Important Information:
Ensure that any existing entry to be replaced has been deleted from Twinfield first
In the overview of journal transactions you can use the 'Resync all' or 'Synchronize failed' buttons to re-synchronize all journal entries at the same time
Error messages
The most common error messages for Twinfield are listed here: Error messages Twinfield